1. Gregg MB (ed.). Field Epidemiology. New York: Oxford University Press, 2002.

2. Reingold A. Outbreak investigation: a perspective. Epidemiol Bull 2000; 21: 1-7.

3. Todd EC. Epidemiology of foodborne disease: a worldwide review. World Health Stat Q 1997; 50: 30-50.

4. Koopman M, von Bonsdorff CH, Vinje J, de Medici D, Monroe S. Foodborne viruses. FEMS Microbiol Rev 2002; 26:187-205.

5. Irani DN, Johnson DT. Diagnosis and prevention of bovine spongiform encephalopathy and variant Creutzfeldt-Jakob disease. Annu Rev Med 2003; 54:305-319.

6. Muyembe-Tamfum JJ, Kipasa M, Kiyungu C, Colebunders R. Ebola outbreak in Kikwit, Democratic Republic of the Congo: discovery and control measures. J Infect Dis 1999; 179(suppl 1): S259-262.

7. von Eiff C, Jansen B, Kohnen W, Becker K. Infections associated with medical devices: pathogenesis, management, and propylaxis. Drugs 2005; 65: 179-214.

8. Owings MF, KozakLJ. Ambulatory and inpatient procedures in the United States, 1996. National Center for Health Statistics. Vital Health Stat 1993; 13(139): http://www.cdc.gov/nchs/data/ series/sr_13/sr13_139.pdf [accessed June 3 2005].

9. Ramsey AH, Oemig TV, Davis JP, Massey JP, Torok TJ. An outbreak of bronchoscopy-related Mycobacterium tuberculosis infections due to lack of bronchoscope leak testing. Chest 2002; 121: 976-981.

10. Agerton T, Valway S, Gore B, Pozsik C et al. Transmission of a highly drug-resistant strain (strain W1) of Mycobacterium tuberculosis. Community outbreak and nosocomial transmission via a contaminated bronchoscope. J Am Med Assoc 1997; 278: 1073-1077.

11. Kressel AB, Kidd F. Pseudo-outbreak of MycobaceriuM. chelonae and Methylobacterium mesophilicum caused by contamination of an automated endoscopy washer. Infect Control Hosp Epidemiol 2001; 22: 414-418.

12. Kolmos HJ, Lerche A, Kristoffersen K, Rosdahl VT. Pseudo-outbreak of Pseudomonas aeruginosa in HIV-infected patients undergoing fiberoptic bronchoscopy. Scand J Infect Dis 1994; 26: 653.

13. Bryce EA, Walker M, Bevan C, Smith JA. Contamination of bronchoscopes with Mycobacterium tuberculosis. Can J Infect Control 1993; 8: 35-36.

14. Fraser VJ, Jones M, Murray PR, Medoff G et al. Contamination of flexible fiberoptic broncho-scopes with Mycobacterium chelonae linked to an automated bronchoscope disinfection machine. Am Rev Resp Dis 1992; 145: 853-855.

15. Gubler, JG, Salfinger M, von Graevenitz A. Pseudoepidemic of nontuberculous mycobacteria due to a contaminated broncoscope cleaning machine. Report of an outbreak and review of the literature. Chest 1992; 101: 1245-1249.

16. Bronchoscopy-related infections and pseudoinfections - New York, 1996 and 1998. Morb Mortal Wkly Rep 1999; 48: 557-560.

17. FDA and CDC Public Health Advisory: Infections from endoscopes inadequately reprocessed by an automated endoscope reprocessing system: http://www.fda.gov/cdrh/safety/endorepro-cess.html [accessed June 3 2005].

18. Kirschke DL, Jones TF, Craig AS, Chu PS et al. Pseudomonas aeruginosa and Serratia marcescens contamination associated with a manufacturing defect in bronchoscopes. N Engl J Med 2003; 348: 214-220.

19. Srinivasan A, Wolfenden LL, Song X, Mackie K et al. An outbreak of Pseudomonas aeruginosa infections associated with flexible bronchoscopes. N Engl J Med 2003; 348: 221-227.

20. Fiddleman R, Magee A, Patt-Corner R, Jewler L et al. Improving patient safety by eliminating problems in the product alert process: http://info.rasmas.mitretek.org/whitePapers.html [accessed June 28 2004].

21. Patterson P. Bronchoscope recall falls through cracks. OR Manager 2002; 18: 20.

22. 1999 National Hospital Discharge Survey: annual summary with detailed diagnosis and procedure data. Vital Health Stat 2001: 13(151): 38.

23. Advance Data from Vital and Health Statistics; No. 300. August 12,1998. Number of ambulatory surgery procedures by procedure category, sex and age: United States, 1996. http://www.cdc. gov/search.do?action=search&queryText=Advance+data+300 [accessed November 24, 2006].

24. Kaczmarek R, Moore RM Jr, McCrohan J, Goldman DA et al. Multi-state investigation of actual disinfection/sterilization of endoscopes in health care facilities. Am J Med 1992: 92: 257-261.

25. Mackeen D. Patients possibly exposed to hepatitis, HIV. Newsday, June 16 2004: http://www.news-day.com/news/health/ny-liendo163852129jun16,0,738070.story [accessed June 29 2004].

26. The Kaiser Papers: http://www.kaiserpapers.org/scaro.html [accessed June 29 2004].

27. King W. 600 University of Washington patients told of cleaning lapse. Seattle Times, March 2004: http://www.iconocast.com/H/Health3B_News20_04/Health7.htm [accessed June 29 2004].

28. Doherty E, Mitchell E, Smyth B. Investigation of the decontamination arrangements for endoscopes in Northern Ireland. Eurosurveillance Wkly 2004; 8(27): http://www.eurosurveil-lance.org/ew/2004/040701.asp#4 [accessed July 1 2004].

29. Durante L, Zulty JC, Israel E, Powers PJ et al. Investigation of an outbreak of bloody diarrhea: association with endoscsopic cleaning solution and demonstration of lesions in an animal model. Am J Med 1992; 92: 476-480.

30. Spach DH, Silverstein FE, Stamm WE. Transmission of infection by gastrointestinal endoscopy and bronchoscopy. Ann Intern Med 1993; 118: 117-128.

31. Research updates in kidney and urologic health: http://kidney.niddk.nih.gov/about/Research_-Updates/sum02/1.htm [accessed June 3 2004].

32. Morbidity and mortality of dialysis. NIH Consens Statement Online, November 1-3 1993; 11(2): 1-33: http://consensus.nih.gov/cons/093/093_statement.htm#1_Introdu [accessed June 3 2005].

33. Welbel SF, Schoendorf K, Bland LA, Arduino MJ et al. An outbreak of Gram-negative bloodstream infections in chronic hemodialysis patients. Am J Nephrol 1995; 15: 1-4.

34. Velandia M, Fridkin SK, Cardenas V, Boshell J et al. Transmission of HIV in dialysis centre. Lancet 1995; 345: 1417-1422.

35. Rudnick JR, Arduino MJ, Bland LA, Cusick L et al. An outbreak of pyrogenic reactions in chronic hemodialysis patients associated with hemodialyzer re-use. Artif Organs 1995; 19: 289-294.

36. Arnow PM, Garcia-Houchins S, Neagle MB, Bova JL et al. An outbreak of bloodstream infections arising from hemodialysis equipment. J Infect Dis 1998; 178: 783-791.

37. Block C, Backenroth R, Gershon E, Israeli R et al. Outbreak of bloodstream infections associated with dialysis machine waste ports in a hemodialysis facility. Eur J Clin Microbiol Infect Dis 1999; 18: 723-725.

38. Flaherty JP, Garcia-Houchins S, Chudy R, Arnow PM. An outbreak of Gram-negative bacteremia traced to contaminated O-rings in reprocessed dialyzers. Ann Intern Med 1993; 119: 1072-1078.

39. Hutter JC, Kuehnert MJ, Wallis RR, Lucas AD et al. Acute onset of decreased vision and hearing traced to hemodialysis treatment with aged dialyzers. J Am Med Assoc 2000; 283: 2128-2134.

40. Hendricks K, Sehulster L, Bell RL, Cousins J et al. Outbreaks of hepatitis B virus infection among hemodialysis patients - California, Nebraska, and Texas. Morb Mortal Wkly Rep 1994; 45: 285-289.

41. Hutin YJ, Goldstein ST, Varma JK, O'Dair JB etal. An outbreak of hospital-acquired hepatitis B virus infection among patients receiving chronic hemodialysis. Infect Control Hosp Epidemiol 1999; 20: 731-735.

42. Maguire H, Watson J, George R, Taylor L et al. A multidisciplinary investigation of a cluster of deaths on a paediatric intensive care unit. J Hosp Infect 1993; 24: 95-108.

43. Svenningsen NW, Bekassy AN, Christensen P, Kamme C. Nosocomial Klebsiella pneumoniae infection: clinical and hygienic measures in a neonatal intensive care unit. Scand J Infect Dis 1984; 16: 29-35.

44. Van der Zwet WC, Parleviliet GA, Savelkoul PH, Stoof J et al. Outbreak of Bacillus cereus infections in a neonatal intensive care unit traced to balloons used in manual ventilation. J Clin Microbiol 2000; 38: 4131-4136.

45. Lemaitre D, Elaichouni A, Hundhausen M, Claeys G et al. Tracheal colonization with Sphingomonas paucimobilis in mechanically ventilated neonates due to contaminated ventilator temperature probes. J Hosp Infect 1996; 32: 199-206.

46. Berthelot P, Grattard F, Patural H, Ros A et al. Nosocomial colonization of premature babies with Klebsiella oxytoca: probable role of enteral feeding procedure in transmission and control of the outbreak with the use of gloves. Infect Control Hosp Epidemiol 2001; 22: 148-151.

47. Brown SL, Bright RA, Dwyer DE, Foxman B. Breast pump adverse events reports to the Food and Drug Administration. J Hum Lact 2005; 21:169-174.

48. Boo N-Y, Nordiah AJ, Alfizah H, Nor-Rohaini AH, Lim VKE. Contamination of breast milk obtained by manual expression and breast pumps in mothers of very low birthweight infants. J Hosp Infect 2001; 49: 274-281.

49. Blenkharn JI. Infection risks from electrically operated breast pumps. J Hosp Infect 1989; 13: 27-31.

50. Mitchell SJ, Gray J, Morgan MEI, Hocking MD, Durbin GM. Nosocomial infection with Rhizopus microsporus in preterm infants: association with wooden tongue depressors. Lancet 1996; 348: 441-443.

51. Holzel H, Macqueen S, MacDonald A, Alexander S et al. Rhizopus microsporus in wooden tongue depressors: a major threat or minor inconvenience? J Hosp Infect 1998; 38: 113-118.

52. Hazard Notice MDA HN 9604 May 1996, Wooden tongue depressor: http://www.medical-devices. gov.uk/mda/mdawebsitev2.nsf/e8be0ee313c493aa80256bbb00307b2e/ d6850ebf02d43d8f80256c8b003aa295/$FILE/hn9604.pdf

53. Shah R, Mackey K, Wallace H, Yawata K et al. Epidemiologic notes and reports hepatitis B associated with jet gun injection - California. Morb Mortal Wkly Rep 1986; 35: 373-376.

54. Canter J, Mackey K, Good LS, Roberto RR et al. An outbreak of hepatitis B associated with jet injections in a weight reduction clinic. Arch Intern Med 1990; 150: 1923-1927.

55. Science and Society Picture Library: http://www.nmsi.ac.uk/piclib/imagerecord. asp?id= 10287525 [accessed June 3 2005].

56. Chen K-T, Chen C-J, Chang P-Y, Morse DL. A nosocomial outbreak of malaria associated with contaminated catheters and contrast medium of a computed tomographic scanner. Infect Control Hosp Epidemiol 1999; 20: 22-25.

57. Malinger G, Ginath S, Zeidel L, Avinoach I et al. Starch peritonitis outbreak after introduction of a new brand of starch-powdered latex gloves. Acta Obstet Gynecol Scand 2000; 79: 610611.

58. Medical glove powder report: http://www.fda.gov/cdrh/glvpwd.html [accessed Jun 3 2005].

59. Nellcor announces nationwide voluntary recall of CapnoProbeTM sensors: http://www.fda.gov/ oc/po/firmrecalls/nellcor08_04.html [accessed September 10 2004].

60. FDA announces a nationwide recall of Nellcor Puritan Bennet probes device: http://www.fda.-gov/bbs/topics/news/2004/NEW01108.html [accessed September 10 2004].

61. Torres J, Murillo J, Bofill L, Raeos A et al. Rapidly growing Mycobacterial infection following liposuction and liposculpture - Caracas, Venezuela, 1996-1998. Morb Mortal Wkly Rep 1998; 47: 1065-1067.

62. Yardy GW, Cox RA. An outbreak of Pseudomonas aeruginosa infection associated with contaminated urodynamic equipment. J Hosp Infect 2001; 47: 60-63.

63. Pressure transducer cover (SensorNor Pressure Dome) for urodynamic system of bladder pressure measurement - risk of cross infection if cover is re-used: http://www.medical-devices.gov.uk/mda/mdawebsitev2.nsf/0/0D57D77D23BB0BBC00256AA400523282?0PEN [accessed June 3 2005].

64. Weems JJ Jr. Nosocomial outbreak of Pseudomonas cepacia associated with contamination of re-usable electronic ventilator temperature probes. Infect Control Hosp Epidemiol 1993; 14: 584-586.

65. Villarino ME, Jarvis WR, O'Hara C, Bresnahan J, Clark N. Epidemic of Serratia marcescens bacteremia in a cardiac intensive care unit. J Clinical Microbiol 1989; 27: 2433-2436.